1244
|
1244 |
SYMAPI_AEVENT2_UID_ALERT_ARR_COMP_STATUS |
|---|---|
|
Category |
status |
|
Component |
Power=xxx Fan=xxx LCC=xxx Enclosure=xxx MM=xxx IOMC=xxx Dir=xxx |
|
Severity |
If Online: Normal If Online Degraded: Warning If Offline: Major If Unknown: Warning |
|
Message |
Component state has changed to [Not Present | Unknown | Online | Write Disabled | Offline | Failed] |
|
Unisphere policy name |
Array Component Events |
|
Action type |
Alert |
- Online — means that the component is a Normal or Degraded state.
- Online [Degraded] — means that the component is in a degraded state.
- Offline — means that the component is in a Failed state.
The format of the specific component name (xxx above) may differ depending on the VMAX model. Some examples you might encounter are:
|
SB-1/Fan-A |
Fan in System Bay |
|
SB-1/ENC-1 |
Enclosure within System Bay |
|
SB-1/ENC-1/Fan-A |
Fan in Enclosure-Slot within System Bay |
|
SB-1/MIBE-L-2A |
MIBE within System Bay |
|
SB-1/MIBE-L-2A/PS-A |
Power Supply in MIBE within System Bay |
Notes
Indicates a change in environmental status for one of the following types of sub-components within the VMAX array:
|
Fans: |
[ Fan ] |
|
Power Supplies: |
[ Power ] |
|
Link Control Cards: |
[ LCC ] |
|
Management Modules |
[ MM ] |
|
IO Module Carriers |
[ IOMC ] |
|
Directors (for environmental alerts): |
[ Dir ] |
|
Enclosures or Matrix Interface Board Enclosures |
[ Enclosure ] |